Multi-view image radiometric calibration and synthesis
Keywords:
Dynamic range, Photometric calibration, Multi-camera, Response characteristicsAbstract
In recent years, visual imaging technology has been developed rapidly, the imaging system is also improving. Single image sensor has been unable to satisfy the demand, which is the large field of view and high dynamic range. Thus, multi-camera systems with large field of view(FOV) have attracted wide attentions. Based on the principle of compound eye imaging, the multi-camera system was used to study its imaging characteristics. Considering the loss in the imaging process and the influence of the lens, the irradiance of the camera was calibrated and the vignetting was corrected. At the same time, the functions of the camera's radiation response and dark current were solved. Then the large FOV image mosaic and high dynamic range imaging of multi-camera system were carried out. Experiments show that radiometric calibration has a good influence on the above imaging. © 2019, Editorial Board, Journal of Applied Optics. All right reserved.
References
Gurrieri L.E., Dubois E., Acquisition of omnidirectional stereoscopic images and videos of dynamic scenes: a review, Journal of Electronic Imaging, 22, 3, (2013)
Popovic V., Afshari H., Schmid A., Et al., Real-time implementation of Gaussian image blending in a spherical light field camera, Industrial Technology (ICIT), 2013 IEEE International Conference on IEEE, pp. 1173-1178, (2013)
Marks D.L., Llull P.R., Phillips Z., Et al., Characterization of the AWARE 10 two-gigapixel wide-field-of-view visible imager, Applied Optics, 53, 13, pp. C54-C63, (2014)
Brady D.J., Gehm M.E., Stack R.A., Et al., Multiscale gigapixel photography, Nature, 486, 7403, pp. 386-389, (2012)
Marks D.L., Son H.S., Kim J., Et al., Engineering a gigapixel monocentric multiscale camera, Optical Engineering, 51, 8, (2012)
Shi L., Cao A., Liu Y., Et al., Design and experiments of artificial compound eye with large view field, Opto-Electronic Engineering, 40, 7, pp. 27-33, (2013)
Cao A., Shi L., Shi R., Et al., Image processing algorithm study of large fov compound eye structure, Acta Photonica Sinica, 43, 5, pp. 193-198, (2014)
Wu B., Fu T., Cheng X., Et al., Calibration experiment for intensity response characteristics of digital color camera, Opto-Electronic Engineering, 33, 6, pp. 101-105, (2006)
Xiu J., Huang P., Li J., Et al., Radiometric calibration of large area array color CCD aerial mapping camera, Optics & Precision Engineering, 20, 6, pp. 1365-1373, (2012)
Wang Y.W., Cai B.L., Lu Y., Et al., Optical system design of artificial compound eye based on field stitching, Microwave & Optical Technology Letters, 59, 6, pp. 1277-1279, (2017)
Debevec P.E., Malik J., Recovering high dynamic range radiance maps from photographs, Conference on Computer Graphics and Interactive Techniques, pp. 369-378, (1997)
Healey G., Kondepudy R., Radiometric CCD camera calibration and noise estimation, IEEE Transactions on Pattern Analysis & Machine Intelligence, 16, 3, pp. 267-276, (2002)
Yu W., Practical anti-vignetting methods for digital cameras, IEEE Transactions on Consumer Electronics, 50, 4, pp. 975-983, (2004)
Li Z., Shen T., Shi H., Et al., Scene-based method to correct vignetting effect of IR optical system, Infrared & Laser Engineering, 44, b12, pp. 8-12, (2015)
Hua S., Wang L., Ou Z., Alignment of images with varying exposure level from a same scene and HDR image construction, Journal of Computer-Aided Design & Computer Graphics, 19, 4, pp. 528-534, (2007)
Published
How to Cite
Issue
Section
License
Copyright (c) 2019 Journal of Applied Optics
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
The CC Attribution-NonCommercial 4.0 License allows sharing and adapting the work, provided the creator is credited and the work is not used commercially. Modifications must be indicated, and derivative works under the same license are allowed.