Research on measurement module of precision infrared radiometer

Authors

  • Yang, Ke

Keywords:

infrared radiometer, phase sensitive detection

Abstract

The infrared radiometer is generally used for the calibration of the infrared thermal imager testing equipment. A measurement module and method for infrared radiometer were introduced. A measurement scheme of sample and hold was designed, the sampling pulse was generated from the reference signal, and the sampling point was set at the 1/4 phase of each signal period, which could significantly improve the measurement ability of weak signals. For the black-body radiation signal at 35 ℃, the measured signal strength could be increased by 57.6% by comparing with the existing scheme. Under the condition that the background temperature of the infrared thermal imager testing equipment was 22 ℃, the measurement signal accuracy could be improved by more than 50% through the comparison test with the existing instruments. © 2022 Editorial office of Journal of Applied Optics. All rights reserved.

References

WANG Xuexin, YANG Hongru, WU Lipeng, Et al., Research on high precision MRTD testing and calibration technology[J], Journal of Applied Optics, 41, 5, pp. 1026-1031, (2020); HU Tieli, LI Xudong, FU Jianming, Et al., Double-blackbody unit for measuring parameters of infrared cameras[J], Journal of Applied Optics, 27, 3, pp. 246-249, (2006); CHEN Zhenxing, Research for infrared imaging system MRTD testing technology, (2011); HU Tieli, SHEN Yue, GUO Yu, Et al., Low noise infrared radiometer[J], Journal of Applied Optics, 34, 4, pp. 663-666, (2013); QIU Chao, ZHAI Siting, WU Kexuan, Et al., Research on low-temperature infrared radiation measurement technology under vacuum condition[J], Journal of Applied Optics, 41, 4, pp. 730-736, (2020); MAO Yunzhi, CHENG Xianhai, HUANG Chuanlu, Improve measurement precision of microwave radiometer by dynamic feedback equalize, Journal of Microwaves, pp. 646-649, (2014); HAN Tuanjun, Design of weak signal extraction circuit based on lock-in amplifier[J], China Sciencepaper, 13, 24, pp. 2804-2808, (2018); WANG Qi, JIANG Chuandong, DU Hailong, Weak signal detection system based on phase-locked amplification with low noise and high gain[J], Experimental Technology and Management, 35, 3, pp. 84-86, (2018); MAO Shengyuan, LUO Xiangdong, ZHOU Chuanhang, Digital lock-in amplifier detects weak modulation signal[J], Laser Journal, 35, 10, pp. 879-884, (2006); LIU Suying, Design of a lock-in amplifier for detecting weak photocurrent signals[J], Journal of Chuzhou University, 20, 2, pp. 41-45, (2018); GAO Jinzhan, Detection of weak signals, (2004); ZENG Qingyong, Detection of weak signals, (1994); YU Bing, WANG Baolong, LI Hongguang, Et al., Research on divergence angle measurement technique of terahertz sources[J], Journal of Applied Optics, 42, 3, pp. 499-503, (2021); XIONG Xianming, ZHANG Haishen, HAN Jiaguang, Et al., The design of phase locked amplifier circuit in Terahertz test system[J], Electrical Measurement & Instrumentation, 54, 7, pp. 89-93, (2017); SUN Zhibin, CHEN Jiagui, Advance of lock-in amplifier[J], Experimental Technology, 35, 10, pp. 879-884, (2006)

Published

30-06-2022

How to Cite

Ke, Y. (2022). Research on measurement module of precision infrared radiometer. Journal of Applied Optics, 43(1), 8–12. Retrieved from https://appliedopticsjournal.net/index.php/JAO/article/view/37

Issue

Section

Original Research Article

Similar Articles

1 2 3 4 > >> 

You may also start an advanced similarity search for this article.