Dynamic modulation transfer function measuring device for photoelectric imaging system
Keywords:
Dynamic target generator, Dynamic transfer functionAbstract
In the optical imaging system, the dynamic modulation transfer function (DMTF) is affected by the wave aberration of optical system, the signal resolution and transfer characteristics of detector modules, and the image blur caused by the carrier motion, which has become one of the important parameters of the photoelectric imaging system. Based on the testing principle of dynamic and static modulation transfer function of photoelectric imaging system, a DMTF measuring device was developed, in which the focal length of optical collimation system was 10 000 mm, and the speed control range of moving target was 30 mm/s~5 000 mm/s, which met the DMTF test of photoelectric imaging system with long focal length. A series of experiments were carried out, and the results show that the repeatability of DMTF measurement is better than 0.01, and the uncertainty of measurement can reach to U= 0.05 (k=2). Copyright ©2021 Journal of Applied Optics. All rights reserved.
References
SU Datu, SHEN Hailong, CHEN Jinbang, Et al., Optical measurement and image evaluation, (1988); HAN Changyuan, Performance optimization of electro-optical imaging systems, Optics and Precision Engineering, 23, 1, pp. 1-9, (2015); FEI Xiang, NI Xuxiang, Present status and development trend of OTF testing insrument, Optical Instruments, 25, 2, pp. 48-52, (2003); ZHU Xiangzhu, ZHANG Jianhui, The characteristic of optical transfer function, Journal of Shaoyang University, 2, 2, pp. 18-20, (2005); TONG Wenquan, Infrared system MTF technology analysis, Infrared, 4, pp. 16-22, (2003); HE Xu, CHEN Qi, Design of key device for CCD camera dynamic MTF testing, Optical Technique, 36, 3, pp. 464-468, (2010); LIU Zhiming, ZHU Ming, CHEN Li, Et al., Long range analysis and compensation of smear in sweep aerial remote sensing, Acta Optica Sinica, 33, 7, (2013); WANG Wanting, GUO Jin, JIANG Zhenhua, Et al., Study of image quality degraded by los jitter, Chinese Journal of Lasers, 41, 4, (2014); YU Xun, SONG Wuhan, WANG Ying, Et al., Dynamic MTF measurement method of clectro-optical systems, Journal of Applied Optics, 34, 6, pp. 928-932, (2013); SERGEY R, OFER H, KOPEIKA N S., Influence of motion sensor error on image restoration from vibrations and motion, Opt. Eng, 4l, 12, pp. 3276-3282, (2002); VOLLMERHAUSEN R, FRIEDMAN M H, REYNOLDS J, Et al., Modeling the blur associated with vibration and motion, 6543, (2007); DONG Zaitian, ZHANG Yijun, TAO Zhong, Et al., Influence of vibration on transfer function of television imaging system, Journal of Applied Optics, 37, 3, pp. 347-352, (2016); BIAN Jiang, MA Dongmei, SUN Ge, MTF test technology anglysis of infrared electro-optical imaging system, Journal of Applied Optics, 34, 5, pp. 748-753, (2013); XU Baoshu, SHI Zelin, FENG Bin, Modulation transfer function measurement method of electro-optical imaging system, Acta Optica Sinica, 31, 11, (2011); ZHANG Muxin, Research on imaging evaluation of CCD camera basing on MTF method, (2015)
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Journal of Applied Optics
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
The CC Attribution-NonCommercial 4.0 License allows sharing and adapting the work, provided the creator is credited and the work is not used commercially. Modifications must be indicated, and derivative works under the same license are allowed.